Trial #1
Positions down for cleaning
There are no related objects.
WR Grace Daraclean 283 at 10% will be used at 150 F for 15 minutes. The parts will then be rinsed in Tap water and then DI water, both for 5 minutes at 150 F. The parts will then be dried under air knives for two minutes and then in a convection oven for 60 minutes at 140 F. After drying, the parts will be examined under a microscope.
Trial #2 will have the part's blind holes facing down coming directly in contact with the Ultrasonic waves.
Trial #2- Looks a heck of a lot better, there appears to be absolutely no fines on the surface of the parts or the screw heads, but there are still a few fines left in the holes most of these are probably burrs. Burrs won't be solved with cleaning, this is a machining issue.
Trial #2- To remove the remaining fines, the cleaning time should be bumped up to 20 minutes and a little rinse agitation should be used.