Default object view. Click to create a custom template, Node ID: 5570, Object ID: 5569

Trial #1

Trial #1

To clean 3 brass conical connectors

1995

4

6

281

282

Part

03/20/1995

0.00

Low Pressure Spray

There are no related objects.

Brass

DI water rinse
Tap water rinse

Goniometry

After the cleaning trial was performed, the parts were subject to contact angle goniometry.  Their contact angle was compared to the contact angle of several dirty parts.  Twenty-three readings were taken of the clean parts.

T&D Finishing Co. TD-110
An average value of 45.043 + 7.081 degrees. Fourteen readings were taken of the dirty parts with an average value of 58.357+ 8.776 degrees.

Valtech Corp. Valtron SP2275
After the parts were subjected to the cleaning trial, they were then subjected to a comparative analysis to dirty parts, using contact angle goniometry. Fourteen readings of the dirty parts were taken, and they had an average contact angle of 58.357 + 8.776 degrees. Twenty-nine readings of the ultrasonically cleaned parts were taken, and they had an average contact angle of 70.828 + 8.414 degrees. This value is unexpectedly higher than that of the dirty parts, suggesting that the clean parts are not as clean as the dirty parts.

No relation

Name Class Section
Document Evaluation #0 Evaluation 3
Document Evaluation #1 Evaluation 3