Trial #1
To evaluate effectiveness of the provided cleaners in regards to removing synthetic blood from stainless steel.
Twelve pre-weighed stainless-steel coupons were soiled with synthetic blood using a swab and allowed to air dry for 24 hours before recording dirty weights. Two additional coupons were weighed but not soiled to provide a control. Two cleaners were prepared using the specified dilutions and temperature: Biogone (RTU at 22 C); Biogone (1:1 at 22 C).
Six coupons per cleaner were immersed in a beaker for two minutes. Coupons were rinsed in a de-ionized water bath for one minute and dried for 28 hours before recording clean weights.
Both dilutions of Biogone were effective at removing the synthetic blood from the stainless-steel coupons.
| Cleaner
|
Initial Wt
|
Final Wt
|
%Removal
|
Average
|
| Biogone RTU
|
0.0253
|
0.0017
|
93.28
|
89.09
|
| 0.0226
|
0.0004
|
98.23
|
| 0.0183
|
0.0020
|
89.07
|
| 0.0257
|
0.0050
|
80.54
|
| 0.0201
|
0.0031
|
84.58
|
| 0.0215
|
0.0024
|
88.84
|
| 0.0066
|
0.0000
|
-
|
|
| Biogone 1:1
|
0.0208
|
0.0003
|
98.56
|
88.29
|
| 0.0258
|
0.0043
|
83.33
|
| 0.0264
|
0.0007
|
97.35
|
| 0.0254
|
0.0028
|
88.98
|
| 0.0259
|
0.0054
|
79.15
|
| 0.0204
|
0.0036
|
82.35
|
| 0.0066
|
0.0000
|
-
|
|
| Biogone 1:2
|
0.0184
|
0.0043
|
76.63
|
75.81
|
| 0.0148
|
0.0036
|
75.68
|
| 0.0213
|
0.0053
|
75.12
|
Both dilutions of Biogone were effective, as an overall average removal of 85% or more is considered effective. The RTU dilution was about 1% more effective than the 1:1 dilution. The product diluted 1:2 removed slightly more than 65%. The results were verified with visual observations.