Trial #0

Trial #0

To measure %T and absorbance of supplied cleaning product collected at one month intervals.

2007

15

5

3

4

Coupon

08/08/2007

0.00

No relation

Jason Marshall

Liquid

None

None

Colorimeter

The experiment measured the percent transmittance and absorbance at 510 nm using a LaMotte’s SMART Colorimeter. The instrument was first zeroed using DI water. Each sample was then measured three times. A 10 ml sample was poured into the glass bottle, capped, wiped and inverted once prior to placing in the instrument. After the reading was recorded, the 10 ml sample was poured back into the larger bottle. Then, a second reading was taken from another 10 ml sample and then finally a third sample. The values were averaged and graphed. Samples were taken from zero month, one month, two months, and three months.

In between each location, a blank reading was taken using DI water.

All three sites showed a decrease in %Transmittance (and an increase and absorbance) from one month to the next. The Bergdales site had the least amount of decrease in the %Transmittance and Syversons had the greatest drop. It was noted that each zero month sample had a %Transmittance greater than 100%. This could result from using DI water as the blank and not the cleaning solution itself. However, all three products showed the same starting point and the trends discovered for each site would have been effected at the same rate for each site of collection. Table 1 list the recorded values for each sample measured. Table 2 summarizes the average results by week. Figures 1 and 2 show the %Transmittance per month and Absorbance per month, respectively.

Table 1. Data Recorded

Sample %T 1 %T 2 %T 3 Ave %T Abs 1 Abs 2 Abs 3 Ave Abs
Bergdales 1 115.00 115.00 115.00 115.00 -0.06 -0.06 -0.06 -0.06
Bergdales 2 83.00 82.00 82.00 82.33 0.08 0.09 0.09 0.09
Bergdales 3 55.00 54.00 55.00 54.67 0.26 0.26 0.26 0.26
Bergdales 4 36.00 35.00 35.00 35.33 0.45 0.45 0.45 0.45
Flahertys 1 115.00 115.00 115.00 115.00 -0.06 -0.06 -0.06 -0.06
Flahertys 2 74.00 74.00 73.00 73.67 0.13 0.13 0.14 0.13
Flahertys 3 43.00 43.00 43.00 43.00 0.37 0.37 0.37 0.37
Flahertys 4 25.00 25.00 25.00 25.00 0.60 0.60 0.60 0.60
Syversons 1 115.00 115.00 115.00 115.00 -0.06 -0.06 -0.06 -0.06
Syversons 2 55.00 57.00 54.00 55.33 0.26 0.25 0.27 0.26
Syversons 3 37.00 36.00 36.00 36.33 0.43 0.44 0.44 0.44
Syversons 4 15.00 15.00 15.00 15.00 0.82 0.81 0.82 0.82
Blank 1 100.00 100.00 99.00 99.67 0.00 0.00 0.00 0.00
Blank 2 99.00 99.00 98.00 98.67 0.00 0.01 0.01 0.01
Blank 3 98.00 97.00 97.00 97.33 0.01 0.01 0.01 0.01
Blank 4 99.00 98.00 98.00 98.33 0.01 0.01 0.01 0.01

Table 2. Average Recordings by Month

Month 1 Ave %T Ave Abs
Bergdales 1 115.00 -0.06
Flahertys 1 115.00 -0.06
Syversons 1 115.00 -0.06
Blank 1 99.67 0.00
     
     
Month 2 Ave %T Ave Abs
Bergdales 2 82.33 0.09
Flahertys 2 73.67 0.13
Syversons 2 55.33 0.26
Blank 2 98.67 0.01
     
     
Month 3 Ave %T Ave Abs
Bergdales 3 54.67 0.26
Flahertys 3 43.00 0.37
Syversons 3 36.33 0.44
Blank 3 97.33 0.01
     
     
Mnth 4 Ave %T Ave Abs
Bergdales 4 35.33 0.45
Flahertys 4 25.00 0.60
Syversons 4 15.00 0.82
Blank 4 98.33 0.01

The %Transmittance decreased for each sample site over time. Bergdales had the lowest decrease and Syversons had the greatest reduction. In order to determine the relevance of this trend, the amount of usage each cleaning system received during the time period should be determined. Without consistent usage, the effectiveness of the filtration system across the three sites may be hard to compare.