Trial #38
To conduct an additional chlorine measurement of solution
There are no related objects.
There are no related objects.
There are no related objects.
The results of the chlorine concentration for the 0.02% solution after sitting for two months was measured.
The products was tested at three dilutions, 10% and 50% and full strength.
One strip of Ecolab Chlorine Test Paper was inserted into each dilution and immediately compared with the color chart provided. The concentration in parts per million were recorded for all dilutions.
| Product
|
Dilution
|
Estimated
|
|
|
|
(ppm)
|
| 9/13/06
|
|
|
| DFC Bleach Stabilizer 0.02%
|
10%
|
10
|
| DFC Bleach Stabilizer 0.02%
|
50%
|
100
|
| DFC Bleach Stabilizer 0.02%
|
100%
|
200
|
|
|
|
|
| 8/14/06
|
|
|
| DFC Bleach Stabilizer 0.02%
|
10%
|
10-50
|
| DFC Bleach Stabilizer 0.02%
|
50%
|
100
|
| DFC Bleach Stabilizer 0.02%
|
100%
|
200
|
|
|
|
|
| 8/2/06
|
|
|
| DFC Bleach Stabilizer 0.02%
|
10%
|
50-75
|
|
|
|
|
| 7/26/06
|
|
|
| DFC Bleach Stabilizer 0.02%
|
50%
|
200
|
|
|
|
|
| 7/13/06
|
|
|
| DFC Bleach Stabilizer 0.02%
|
50%
|
200
|
| DFC Bleach Stabilizer 0.02%
|
10%
|
50-75
|
The 0.02% Cogent Bleach Stabilizer was found to have maintained its concentration after sitting for two months.