Evaluation of successful products using ultrasonics

2002

10

4

13

13

Coupon

08/07/2002

2.00

Ultrasonics

Jason Marshall

Aluminum

Fluxes
Resins/Rosins
Solder

Tap water rinse

Air Knives

Gravimetric

Five products were selected from the previous trial based on their high efficiencies. The solutions were used at 68 F. The three semi-aqueous products were used at full strength and the two aqueous based products were diluted to 10% in 600 ml beakers using DI water.
Fifteen preweighed coupons were coated with Alpha Metals 615 Flux (67-63-0, 8052-41-3, 8050-09-7) using a handheld swab and allowed to dry. Coupons were then reweighed. Three coupons were cleaned in each solution for 5 minutes using stir-bar agitation, then rinsed in tap water at 68 F for 15 seconds followed by an air knife drying for 30 seconds. Once dry, final weights were recorded and efficiencies were calculated.

All five products were very effective using ultrasonics for two minutes. Table 1 lists the efficiencies for each coupon cleaned.

Table 1. Cleaning Efficiencies

Cleaner Initial wt of cont. Final wt of cont. %Cont Removed
Bio T Max 0.0414 -0.0003 100.72
  0.1571 -0.0003 100.19
  0.1283 0.0004 99.69
DS 108 0.1235 0.0026 97.89
  0.0982 0.0003 99.69
  0.1142 -0.0005 100.44
Ionox HC 2 0.1354 -0.0001 100.07
  0.1060 -0.0003 100.28
  0.1274 -0.0008 100.63
SWR One 0.0916 -0.0002 100.22
  0.1154 -0.0009 100.78
  0.0942 -0.0006 100.64
Beyond 2005 0.0949 0.0061 93.57
  0.1050 0.0002 99.81
  0.1306 0.0015 98.85

These five products will be used on supplied parts from client.