Default object view. Click to create a custom template, Node ID: 6412, Object ID: 6411

Trial #8

Trial #8

To conduct on site testing to replace methyl ethyl ketone in the removal of lacquer from aluminum parts.

2008

15

9

SV2

169

169

Part

05/01/2008

0.00

Ultrasonics

There are no related objects.

Aluminum

Resins/Rosins

There are no related objects.

There are no related objects.

Visual

Follow up conversations with the company revealed that the company was going with the Buckeye Shopmaster RC product based on low odor and superior performance. Also, the VOC’s of the Actisolv were about 900 g/l while the Buckeye was a 100g/l, giving them about and 85% reduction in VOC’s for this application.

The company was getting more product form the distributor for more trials and wanted to work on keeping the temperature in the ultrasonic steady.

The lab went down to the facility to pick up the two smaller units and drop off a larger, approximately 5-gallon, unit with heat and ultrasonics so that they may test in larger batches the Buckeye product. The lab supplied the company with contact information for Branson, Crest, Degreasing Devices and Ken Howard, who makes custom used units.

The company sent the lab some testing results from their own testing. The supplied some additional action items but it still seems they are going to move forward with the substitution. A final follow conversation will be scheduled in early July 2008.

No relation

Powered by eZ Publish™ CMS Open Source Web Content Management. Copyright © 1999-2014 eZ Systems AS (except where otherwise noted). All rights reserved.