Default object view. Click to create a custom template, Node ID: 6629, Object ID: 6628

Trial #5

Trial #5

To evaluate past successful cleaners on new contaminant

2002

10

2

19

19

Coupon

08/25/2002

5.00

Ultrasonics

Jason Marshall

Aluminum

Tap water rinse

Air Knives

Gravimetric

The four successful products from the previous trial were again used at full strength and room temperature. An additional product was added to the trial for comparative purposes. All five products were used in 600 ml beakers and degassed for 5 minutes in a Crest 40 kHz ultrasonic tank. Fifteen preweighed coupons were coated with Emerson & Cuming Eccocoat CC 40A Solvent based conductive coating (7440-22-4, 108-88-3, thermoplastic resin) using a hand held swab. Coupons were allowed to sit for 20 minutes and then weighed again. Three coupons were cleaned in each beaker for 5 minutes using ultrasonics. Coupons were rinsed for 15 seconds in a tap water bath at 68 F and dried for 2 minutes using air knives also at 68 F. Once dried, final weights were recorded and efficiencies calculated for each cleaner.

Only two products, both Bio Chem Systems products, removed the contaminant from the coupons. The table lists the efficiencies for each coupon cleaned.

Table 1. Efficiencies

Cleaner Initial wt Final wt % Removed
Bio T Max 0.7841 0.0024 99.69
  0.4790 0.0011 99.77
  1.1946 0.0022 99.82
DS 108 0.5712 0.5412 5.25
  1.4127 1.3377 5.31
  1.2168 1.1482 5.64
Solsafe 245 1.1079 0.2986 73.05
  0.9153 0.0279 96.95
  1.0718 0.4154 61.24
Ionox HC 2 0.9056 0.8900 1.72
  0.8696 0.8589 1.23
  0.6043 0.5981 1.03
Metabolix 1.0480 1.0011 4.48
  0.7915 0.7707 2.63
  1.2215 1.1370 6.92

The four original effective cleaners will be used to clean the remaining contaminant.