The Enviro Caddie measurements for the Drager tubes for the four compounds resulted in levels exceeding the capabilities of the tubes. The results are listed in the table below.
| Temperature 78.2
|
|
| Humidity 38%
|
|
| Date: July 12, 2002
|
|
| Exposure Evaluation 1
|
|
| Measurement Location:
|
Spray Chamber 12" x 12" x 12"
|
|
|
Acrylic lined with paper towels
|
|
|
3.5" x 4.5" opening in top of chamber for spraying
|
|
|
(2) 1/4 " holes for tubing and Dragger tubes, 1" from opening
|
| Time: 10 sec EC
|
|
| Analysis Method
|
OVM, Thermo Environmental Instruments,Inc - Model 580 B
|
|
|
Dragger tubes for Acetone, Ethyl Benzene, Toulene & Xylene
|
|
|
|
|
|
|
|
|
Background
|
| OVM
|
0.9 ppm
|
| Acetone
|
No Color Change
|
| Ethyle Benzene
|
No Color Change
|
| Toulene
|
No Color Change
|
| Xylene
|
No Color Change
|
|
|
|
|
|
Enviro Caddie
|
| OVM
|
|
| initial (max)
|
508 ppm
|
| 10 sec
|
300 ppm
|
| level
|
265 ppm
|
| Acetone 10 pumps
|
> 1200 ppm
|
| OVM
|
|
| initial (max)
|
1064 ppm
|
| 10 sec
|
272 ppm
|
| level
|
255 ppm
|
| Ethyl Benzene 6 pumps
|
> 600 ppm
|
| OVM
|
|
| initial (max)
|
1096 ppm
|
| 10 sec
|
309 ppm
|
| level
|
309 ppm
|
| Toulene 5 pumps
|
> 400 ppm
|
| OVM
|
|
| initial (max)
|
1063 ppm
|
| 10 sec
|
242 ppm
|
| level
|
232 ppm
|
| Xylene 5 pumps
|
> 400 ppm
|
| 1 pump over max
|
|
|
|
|
| Process
|
Paint was sprayed for 10 seconds into the acrylic chamber
|
|
|
A reading was taken with the OVM initially (max reading), at 10 seconds and then when level
|
|
|
This was done for each of the 4 Dragger tubes
|
|
|
Paper towels were changed between spraying in order to get a fresh reading
|