Equal length strips of the supplied tin wire were cut to place in a 10 ml glass vial containing full strength products at room temperatures. Each strip was weighed to establish a baseline weight. Strips were immersed in a solution for 24 hours. The pieces were then removed and wiped to remove any residual cleaning product. Final weights were measured, and weight loss was determined. Observations were made during the 24-hour period.
During the compatibility test, no visual signs of damage were noted for any of the four products. Only one product, DS 144, had a weight change greater than 0.1%. One product, Ionox HC 2, had a slight increase in weight. Initial weights, final weights, weight change and percent change are listed in the table below.
| Product
|
Initial Wt
|
Final Wt
|
Change
|
% Change
|
| SC Actisolv
|
0.0981
|
0.0980
|
0.0001
|
0.10
|
| Ionox HC 2
|
0.1058
|
0.1059
|
-0.0001
|
-0.09
|
| DS 144
|
0.0970
|
0.0966
|
0.0004
|
0.41
|
| IPA
|
0.0904
|
0.0903
|
0.0001
|
0.11
|