Follow up evaluation of spray rinse.

2002

9

4

103

103

Coupon

04/11/2002

2.00

Ultrasonics

Jason Marshall

Stainless Steel

Tap water rinse

Air Knives

There are no related objects.

Fifteen preweighed coupons were coated with four contaminants from the previous trials. Three coupons were coated with the different contaminants. Bencyn B-5186 (64742-52-5, 9003-29-6, 39464-69-2, 63197-48-8), The Valvoline Co, Tectyl 505 (8052-41-3), C.A. Wood C-Eblis Cutting Fluid (64742-53-6, 64742-52-5) and ITW Devcon Safetap Stick grease. Coupons were reweighed. The fifteen coupons were hung on a metal stand and immersed into a Crest 40 kHz ultrasonic tank and cleaned for 1 minutes using ultrasonics at 92 F, removed and rinsed in a tap water bath and re-immersed into the ultrasonics for an additional 1 minute followed by a second 5 second rinse. The coupons were then dried using an air knife for 15 seconds.

None of the contaminants were removed to any great extent under these cleaning/rinsing methods. Three of the four were removed between 70 and 80% of the contaminant. The Bencyn contaminant was only removed at 17%.

Cleaner Coupon 1 Coupon 2 Coupon 3 Average Std Dev
Bencyn 29.62 16.95 3.99 16.85 12.82
Tectyl 74.97 65.82 71.53 70.77 4.62
C-Eblis 76.66 73.7 82.65 77.67 4.56
Safetap 89.47 69.41 79.29 79.39 10.03

Using ultrasonic cleaning in conjunction without a spray rinse was shown not to be an effective cleaning process for the four contaminants.