Default object view. Click to create a custom template, Node ID: 5493, Object ID: 5492

Trial #2

Trial #2

Further evaluation to separate the leaded glass from the unleaded glass with out using Nitric Acid

1998

6

4

77

77

Part

10/18/1998

30.00

Immersion/Soak

Jason Marshall

Glass/Quartz

Adhesive

Tap water rinse

None

Visual

The back tip of the monitor was broken off to release the vacuum. The part was placed into a bath of Citrinox (2%) at 150 F. The monitor was left in the heated bath for four minutes. At the end of this cycle, the monitor was placed into a tap water bath at room temperature for two minutes. The part was returned to the first Citrinox bath for another four minutes. The hot acid ~ cool water cycle was repeated for four times.
SUBSTRATE MATERIAL: Monitor screens with leaded and unleaded glass
CONTAMINANTS: Frit and adhesive

After the fourth cycle, the monitor had not shown any signs of separation.  The monitor was allowed to sit in the heated Citrinox bath for ten minutes.  From the extended hot bath, the monitor was placed into a room temperature water bath.  At this point a popping sound was heard and a crack had formed.  A second extended hot bath soak resulted in the separation of the screen.  The only problem was the separation did not form at the desired location.

Due to the undesired crack location, the next phase of testing will involve a prescoring of the monitors along the desired interface.  Further testing may involve using only hot and cold water instead of the acidic cleaner now being tested.