Default object view. Click to create a custom template, Node ID: 6528, Object ID: 6527

Trial #6

Trial #6

To evaluate selected products on second type of supplied parts using ultrasonic cleaning

2007

14

3

91

91

Part

03/08/2007

2.00

Ultrasonics

Jason Marshall

Stainless Steel

Tap water rinse

Air Blowoff

Visual

Five products were selected from previous trial based on effectiveness. One product was diluted to 10% using DI water and the other four were used at full strength in 600 ml beakers. Each solution was heated to 130 F in a Crest 40 kHz ultrasonic tanked filled with water. The solutions were degassed for 5 minutes.

Five stainless steel rings without a lacquered finish and coated with Jackonslea Grey Color 305 A (1344-28-1) were cleaned in each solution at 1-minute intervals using 40 kHz ultrasonic cleaning. Rings were rinsed for 15 seconds in 120 F tap water and dried using compressed air at room temperature for 30 seconds. If the rings were not completely clean after the initial 1 minute, the rings would be cleaned for another 1 minute. In addition, if the rings were not completely cleaned after 5 minutes, cleaning would be stopped.

All five products worked in under 4 minutes of cleaning. The table lists the observations for each ring cleaned at the various time intervals.
Order of observations from worst to best: Not clean<Almost clean<Nearly clean<Clean

Cleaner Observation
Bio T Max Almost clean at 1 minute
  Nearly clean after 2 minutes
  Cleaned at 3 minutes
Solsafe 245 Not clean at 1 minute
  Almost clean after 2 minutes
  Nearly clean after 3 minutes
  Cleaned at 4 minutes
DS 104 Not clean after 1 minute
  Almost clean after 2 minutes
  Nearly clean after 3 minutes
  Clean after 4 minutes
Optisolv OP 7168 Almost clean after 1 minute
  Clean after 2 minutes
D Greeze 500 Lo Not clean after 1 minute
  Nearly clean after 2 minutes
  All clean after 3 minutes

All five cleaners worked well in under 4 minutes of cleaning on both types of rings, unlacquered and lacquered. Parts have been sent back for inspection.