Default object view. Click to create a custom template, Node ID: 27976, Object ID: 49148

Trial #0

Trial #0

To evaluate the efficacy of sludge removal (DCC-17) on a hard surface over a span of 10 days.

2023

30

1

27

28

Coupon

02/20/2023

14,400.00

Immersion/Soak

Stainless Steel

DCC-17

None

None

Gravimetric
Visual

Initial weights of fifteen coupons, three per flask, will be recorded before applying 0.25g of DCC-17 to each coupon using a sterile swab. Contaminated weights will be recorded 24 hours after air drying at room temperature. Coupons will be immersed in the solution, either a product/ autoclaved minimal media or a control of deionized (DI) water/ autoclaved minimal media mixture, and incubated at 30°C and shaken (200rpm) for 10 days before final weights and observations are taken.

Protocol for 1L of Minimal Media:
- 7.50 g Bacto peptone media
- 3.27g Bushnell Hass Broth
- 1 Liter DI Water

Coupons in the control flask had similar gravimetric and visual removal as the client and comparative products most likely due to the addition of agitation. 

Cleaner Final wt. of cont. %Cont Removed % AVG
Instant Power
RV and Marine Holding Tank Treatment
0.0012 99.52 99.63
0.0007 99.73
0.0009 99.65
Roebic RV and Marine Holding Tank Treatment  0.0031 98.79 99.05
0.0010 99.62
0.0031 98.73
Instant Power
Septic Shock 
0.0042 98.33 98.89
0.0022 99.14
0.0020 99.21
Roebic
Septic System Cleaner
0.0004 99.84 99.65
0.0006 99.76
0.0017 99.33
DI Water 0.0018 99.30 99.15
0.0025 99.00
0.0022 99.14

The Instant Power RV and Marine Holding Tank Treatment and Septic Shock were as effective as the competitor products at removing sludge from stainless steel. 

No relation

Name Class Section
Document Evaluation #0 Evaluation 3
Document Evaluation #1 Evaluation 3
Document Evaluation #2 Evaluation 3
Document Evaluation #3 Evaluation 3