Default object view. Click to create a custom template, Node ID: 4219, Object ID: 4218

Project #1

Project #1

To deflux electronic assemblies

No

No

No

02/27/1996

David Norton

high voltage multiplier

50% ceramic, 25% silver, 25% solder

5 g

10 g

0.7 x 0.6 inches

Small

Less than 1 lb

Smooth

Hard

Complex

Yes

Fluxes
Rust/Scale

Yes

soldering

touch up

Vapor Degreasing

home made vapor degreaser

Genesolve 2004

room

2

Genesolve 2004 has to go away (HCFC 141 B)

To remove flux to eliminate ionic contamination. The flux is RMA

none

None

Used Immediately

Visual, microscopic

In process testing as a unit, final humidity test

Low ionic contamination on cleaned part to pass performance tests and humidity tests.

After testing several cleaners, one was found to work well. Church & Dwight Armakleen E2002 was suggested by the lab. A summer intern was hired to implement the testing.

Yes

No

No

No

Yes

Name Class Section
Document Trial #0 Trial 3
Powered by eZ Publish™ CMS Open Source Web Content Management. Copyright © 1999-2014 eZ Systems AS (except where otherwise noted). All rights reserved.