Default object view. Click to create a custom template, Node ID: 35506, Object ID: 56836

Trial #1

Trial #1

To evaluate the effectiveness of the client's degreasing product compared to other degreasing products on the market.

2023

32

2

0

0

Coupon

12/09/2023

0.00

Manual Wipe

Amelia Wagner

Painted metal

DCC-17

None

None

Gravimetric

Two products were tested; Formula 409, and KH-7 (client's product).  A total of six coupons were used, three per cleaner, were weighed.  The coupons were then soiled with DCC-17 soil.  About 0.5 grams of the soil was applied to each coupon by using a swab to apply the soil in a line down the center of the coupon.  The weight of the soiled coupons were recorded.  Three coupons at a time were then placed in the Gardner Straight Line Washability Unit.  Wypall cleaning cloths were attached to the cleaning block used for the test. Each Wypall cloth and all coupons received two sprays of the cleaner (2.5 ml total), and the SLW unit was run for 20 cycles (Equivalent to 30 seconds of cleaning). Final weights were taken after air drying at room temperature.

Cleaner Initial wt of cont. Final wt of cont. %Cont Removed % AVG
Formula 409 0.1041 0.0015 98.56 97.75
0.0491 0.0023 95.32
0.0809 0.0005 99.38
KH 7 0.0408 0.0064 84.31 84.76
0.0861 0.0115 86.64
0.0492 0.0082 83.33

Both products were effective in removing DCC17 soil from painted metal, however the Formula 409 did perform better than the KH-7

No relation

Name Class Section
Document Evaluation #0 Evaluation 3
Document Evaluation #1 Evaluation 3