Trial #1
To further evaluate successful cleaners on additional contaminants.
Four cleaners were selected from the previous trial based on the effective cleaning results obtained. All were diluted to 5% by volume using DI water in 600 ml beakers and heated to 130 F in the ultrasonic tank filled with tap water. Twelve preweighed coupons were coated with the grease using a swab and weighed a second time. Three coupons were immersed in the beakers in the ultrasonic unit. Initial observations were made at 5 minute intervals. After 20 minutes, coupons were removed from the ultrasonic energy and rinsed for 30 seconds in tap water at 120 F. Drying was performed with a Master Appliance Corp, Hot-air gun model HG-301A for one minute at 500 F. Coupons were weighed a final time and cleaning efficiencies were calculated.
SUBSTRATE MATERIAL: Aluminum Coupons
CONTAMINANTS: Cello-Seal, Grease
CONTAMINATING PROCESS USED: Grease applied using hand held swab
The Today & Beyond and United Laboratories’ products were successful in removing 90% of the grease from the aluminum coupons. The WR Grace product had one coupon that was 93% clean but the other two coupons were well under 50%. Table 2 shows the efficiencies for the four cleaners evaluated in the trial.
Table 2. Final Coupon Weights
| 20 minutes
|
Heatbath
|
T&B
|
UL
|
WR Grace
|
| Coupon 1
|
32
|
99.21
|
97.19
|
30.03
|
| Coupon 2
|
52.79
|
90.36
|
81.6
|
43.21
|
| Coupon 3
|
23.9
|
97.85
|
91.08
|
92.71
|
| Average
|
36.23
|
95.81
|
89.95
|
55.32
|
The uncleaned parts will be cleaned in the Today & Beyond and United Laboratories products using ultrasonic energy. The clean parts will be returned for inspection by the client.