Default object view. Click to create a custom template, Node ID: 7038, Object ID: 7037

Trial #15

Trial #15

To evaluate three cleaners on second contaminant using vapor degreasing

2004

11

3

96

96

Coupon

05/11/2004

15.00

Vapor Degreasing

Jason Marshall

Steel

Oil

Vapor

Air dry

Gravimetric

Three products were selected based  on results from previous trials.  All products were used heated to  160 F on a hot plate in 250 ml beakers. Nine preweighed steel coupons were coated with Rochester Midland RI780 rust preventative (80252-41-3, 95-63-6) using a hand held swab.  The oil was then heated with a Master Appliance Heat gun at 300 F for 10 minutes.  After cooling to room temperature, a second weighing was performed to determine the amount of soil that was added. Three coupons were cleaned in each solution for 15 minutes in the bench top vapor degreaser.  After cooling, coupons were weighed a final time to determine the cleaning efficiency of each product.

All three products removed over 99% of the oil within 15 minutes of degreasing. Observations note that most of the oil was removed within the first 5 minutes of vapor exposure.  The table lists the amount of soil added, the amount remaining and the efficiency for each coupon.

Cleaner Initial wt Final wt % Removed
Solvon PB 0.0876 -0.0004 100.46
  0.1147 0.0003 99.74
  0.1092 0.0005 99.54
Ensolv A 0.1206 0.0001 99.92
  0.0406 0.0002 99.51
  0.0245 -0.0002 100.82
Metalnox M6960 0.0781 -0.0002 100.26
  0.0374 -0.0003 100.80
  0.0338 0.0007 97.93

The same products will be evaluated under the same conditions for the varnish contaminant.

No relation

Name Class Section
Document Evaluation #0 Evaluation 3
Document Evaluation #1 Evaluation 3
Document Evaluation #2 Evaluation 3