Default object view. Click to create a custom template, Node ID: 7031, Object ID: 7030

Trial #8

Trial #8

To evaluate ultrasonic energy for cleaning the supplied parts.

2004

11

4

35

35

Part

01/21/2004

10.00

Ultrasonics

Jason Marshall

Steel

Oil

None

Air Blowoff

Visual

One product was used at 10%, diluted with DI water and heated to 120 F. The solution was poured into a Branson 200 ultrasonic cleaning system and de-gassed for five minutes. One part was immersed into the solution and cleaned for 10 minutes with 40 kHz ultrasonic energy. The part was dried using air blow off at room temperature for 30 seconds.

Ultrasonics was very effective in cleaning the punch and arbor parts.

Ultrasonic energy would be an effective method for removing the quench oil and gray film on the punch part and the quench oil from the arbor part.