Trial #1

Trial #1

Determine different way to check for cleanliness

1997

5

5

36

42

Coupon

08/26/1997

0.00

Immersion/Soak

Jason Marshall

Steel

There are no related objects.

None

None

Microphotography

To determine a different way to check samples for cleanliness. The current method involves taking a sample and cutting it apart so that the area in question can be viewed. A Microcam/stereomicroscope combination was selected as an alternative method.

SUBSTRATE MATERIAL: Steel
CONTAMINANTS: Unknown
CONTAMINATING PROCESS USED: Samples received cleaned from client

Photographs showed that the sample parts were void of any significant contaminants.  See attached sheet for photographs.

The Microcam/stereomicroscope proved to be a viable method to analyze the clients sample parts.