Default object view. Click to create a custom template, Node ID: 23130, Object ID: 23292

Trial #3

Trial #3

To determine if the aqueous cleaners are stripping the steel coupons provided by the company.

2020

27

2

0

0

Coupon

02/18/2020

0.00

Ultrasonics

There are no related objects.

Steel

There are no related objects.

Ultrasonic

Heat Gun

Gravimetric

Three sets of three steel coupons were weighed and immersed into three distinct beakers containing Aquavantage 1400 GD, Liquinox, and SC-1000 respectively. Heated ultrasonics was conducted at 122-125°F for 15 minutes. Coupons were submerged in three distinct beakers containing deionized water as a rinse step for 5 minutes. Coupons were dried with an air gun for 10 minutes. Effectiveness of cleaning was observed gravimetrically after the drying step. 

After 15 minutes of heated ultrasonics and subsequent post-treatment, coupons treated with Aquavantage 1400 GD and Liquinox lost a thousandth of a gram, while coupons cleaned with SC-1000 lost a hundredth of a gram.

Based on gravimetric analysis, Liquinox on average had the least amount of weight lost for the steel coupons. Coupons cleaned with both Liquniox and Aquavantage 1400 GD lost a thousandth of a gram. Coupons cleaned with SC-1000 lost a hundredth of a gram. The next step would be to continue testing with the vanishing oil contaminant provided by the company.