Cleaning Solution: 5% solution of Abatement Technologies Bio Might 100.
Cleaning Temperature (F): 127
Tap Water Rinse Temperature (F): 140
DI Water Rinse Temperature (F): 138
GRAVIMETRIC ANALYSIS
| sample # /
|
clean mass
|
mass with
|
mass after
|
contaminant
|
Percent
|
| substrate
|
(g)
|
cont (g)
|
cleaning (g)
|
removed (g)
|
Removal
|
| 8641
|
36.0927
|
36.1138
|
36.0919
|
0.0219
|
103.79%
|
| 9039
|
36.1334
|
36.176
|
36.1337
|
0.0423
|
99.30
|
| 0268*
|
36.2572
|
36.2904
|
36.257
|
0.0334
|
100.60%
|
| Average
|
|
|
|
|
101.23%
|
| StDev.
|
|
|
|
|
2.31%
|
| Cleaning Solution: 5% Solution of Gemtek SC1000
|
| Cleaning Temperature (F): 128
|
| Tap Water Rinse Temperature (F): 145
|
| DI Water Rinse Temperature (F): 140
|
| GRAVIMENTRIC ANALYSIS
|
|
|
|
|
|
| sample # /
|
clean mass
|
mass with
|
mass after
|
contaminant
|
Percent
|
| substrate
|
(g)
|
cont (g)
|
cleaning (g)
|
removed (g)
|
Removal
|
| 6169
|
35.8442
|
35.8708
|
35.8451
|
0.0257
|
96.62%
|
| 9477
|
36.1767
|
36.2059
|
36.1782
|
0.0277
|
94.86%
|
| 0920*
|
36.3223
|
36.3722
|
36.3256
|
0.0466
|
93.39%
|
| Average
|
|
|
|
|
94.96%
|
| StDev.
|
|
|
|
|
1.62%
|
| Cleaning Solution: 5% solution of Cleaning Systems Inc. Release
|
| Cleaning Temperature (F): 136
|
| Tap Water Rinse Temperature (F): 144
|
| DI Water Rinse Temperature (F): 138
|
| GRAVIMETRIC ANALYSIS
|
| sample # /
|
clean mass
|
mass with
|
mass after
|
contaminant
|
Percent
|
| substrate
|
(g)
|
cont (g)
|
cleaning (g)
|
removed (g)
|
Removal
|
| 8803
|
36.1093
|
36.1384
|
36.1095
|
0.0289
|
99.31%
|
| 7634
|
35.992
|
36.0519
|
35.9916
|
0.0603
|
100.67%
|
| 9967*
|
36.2262
|
36.2621
|
36.2264
|
0.0357
|
99.44%
|
| Average
|
|
|
|
|
99.81%
|
| StDev.
|
|
|
|
|
0.75%
|
| Cleaning Solution:4% Solution of Valtech Valtron SP 2275
|
| Cleaning Temperature (F): 137
|
| Tap Water Rinse Temperature (F): 142
|
| DI Water Rinse Temperature (F): 141
|
| GRAVIMETRIC ANALYSIS
|
| sample # /
|
clean mass
|
mass with
|
mass after
|
contaminant
|
Percent
|
| substrate
|
(g)
|
cont (g)
|
cleaning (g)
|
removed (g)
|
Removal
|
| 8345
|
36.0630
|
36.0928
|
36.0645
|
0.0283
|
96.92%
|
| 6257
|
35.8533
|
35.8768
|
35.8532
|
0.0236
|
100.43%
|
| 7133*
|
35.9418
|
35.9667
|
35.9419
|
0.0248
|
99.60%
|
| Average
|
|
|
|
|
98.98%
|
| StDev.
|
|
|
|
|
1.83%
|
|
|
|
|
|
|
|
| Cleaning Solution: Calgon Geo-Guard #2215
|
| Cleaning Temperature (F): 139
|
| Tap Water Rinse Temperature (F): 140
|
| DI Water Rinse Temperature (F): 139
|
| GRAVIMETRIC ANALYSIS
|
| sample #
|
clean mass
|
mass with
|
mass after
|
contaminant
|
Percent
|
| substrate
|
(g)
|
cont (g)
|
cleaning (g)
|
removed (g)
|
Removal
|
| 8385
|
36.0679
|
36.0965
|
36.0676
|
0.0289
|
101.05%
|
| 8840
|
36.1134
|
36.1451
|
36.1130
|
0.0321
|
101.26%
|
| 6968*
|
35.9251
|
35.9422
|
35.9242
|
0.0180
|
105.26%
|
| Average
|
|
|
|
|
102.52%
|
| StDev.
|
|
|
|
|
2.37%
|
| Cleaning Solution: Valtech Valtron 2201
|
| Cleaning Temperature (F): 146
|
| Tap Water Rinse Temperature (F): 142
|
| DI Water Rinse Temperature (F): 138
|
| GRAVIMETRIC ANALYSIS
|
| sample # /
|
clean mass
|
mass with
|
mass after
|
contaminant
|
Percent
|
| substrate
|
(g)
|
cont (g)
|
cleaning (g)
|
removed (g)
|
Removal
|
| 9854
|
36.2155
|
36.2550
|
36.2153
|
0.0397
|
100.51%
|
| 6643
|
35.8927
|
35.9254
|
35.8918
|
0.0336
|
102.75%
|
| 8028*
|
36.0314
|
36.0491
|
36.0307
|
0.0184
|
103.95%
|
| Average
|
|
|
|
|
102.40%
|
| StDev.
|
|
|
|
|
1.75%
|