Trial #6

Trial #6

To evaluate the effectiveness of seven TCE alternatives at removing lubricant from aluminum alloys.

2017

25

1

0

0

Coupon

07/24/2017

5.00

Ultrasonics

Aluminum

None

None

Gravimetric
Visual

Preweighed aluminum coupons were tested for each aqueous cleaner. Coupons were soiled with Blasocut 2000 Universal Lubricant (CAS: 64742-52-5; 61790-44-1; 68608-26-4; 63449-39-8; 107-41-5; 770-35-4) using a swab to cover the bottom third of the substrate and dirty weights were recorded. Chemistries were prepared with a five percent dilution except for Micro 90, which had a two percent dilution based on vendor recommendations. Coupons were immersed, three at a time, in a beaker filled with 200ml of the chosen cleaner at room temperature (68 F) for five minutes. Final weights were taken after cleaning.

Cleaner Initial wt. Final wt. % Removed Average %
SC Aircraft & Metal Cleaner(5%)        
  0.0413 0.1333 -222.76 -141.9
  0.0635 0.1218 -91.81  
  0.0727 0.1535 -111.14  
Amberclean 527L (5%)        
  0.0972 0.1491 -53.40 -20.81
  0.1293 0.1246 3.63  
  0.1624 0.1830 -12.68  
Surface Cleanse 930 (2%)        
  0.1228 0.2027 -65.07 -47.86
  0.1627 0.2314 -42.22  
  0.1397 0.1904 -36.29  
Micro 90 (2%)        
  0.1509 0.2287 -51.56 -49.53
  0.1844 0.2740 -48.59  
  0.1810 0.2687 -48.45  
Solution 2000 (5%)        
  0.1726 0.2784 -61.30 -76.37
  0.1366 0.2552 -86.82  
  0.1283 0.2322 -80.98  
Shopmaster (5%)        
  0.1744 0.2277 -30.56 -48.64
  0.1267 0.2300 -81.53  
  0.1614 0.2160 -33.83  
Crystal Simple Green (5%)        
  0.1419 0.1186 16.42 29.34
  0.1284 0.1079 15.97  
  0.0978 0.0434 55.62  

The Blasocut 2000 Universal Lubricant looked saturated with the aqueous cleaners which could have led to having negative final weights. Coupons visually looked cleaner, but it was not reflected in gravimetric results.

None of the products were very effective at removing Blasocut 2000 Universal gravimetrically, but signs of removal was observed visually. Next step is to try unheated ultrasonics for five minutes to compare with the drop-in solvents.

No relation

Name Class Section
Document Evaluation #0 Evaluation 3
Document Evaluation #1 Evaluation 3
Document Evaluation #2 Evaluation 3
Document Evaluation #3 Evaluation 3
Document Evaluation #4 Evaluation 3
Document Evaluation #5 Evaluation 3
Document Evaluation #6 Evaluation 3
Powered by eZ Publish™ CMS Open Source Web Content Management. Copyright © 1999-2014 eZ Systems AS (except where otherwise noted). All rights reserved.