Vinyl composite tiles were coated using the supplied product and a conventional floor coating. A known amount of coating was first applied to the surface and then smoothed using a 10-mil blade to ensure consistent thickness of the coating across the VCT.
Two grams of AATCC soil was sprinkled across the portion of the tile over which the roller will track. The roller was run for 300 cycles (600 passes) across the surface. During the cycling, it was necessary to occasionally brush the soil back onto the track as it gets scattered by the motion of the roller. At the end of the test, the surface was wiped with tissue to remove any loose soil, wiping firmly, but not bearing down.
Results were done in a comparative manner by both examining the soiled test polish and rating it versus a standard polish.
The success of the coating to resist soil is demonstrated by the coated coupon's light readings to be as close to the baseline readings. The wiped final readings of each coupon were compared with the baseline readings obtained for each coupon.