Trial #1
To evaluate the efficiency of various heated drop in solvent replacements removing DOW Corning Vacuum Grease from Stainless Steel substrates .
2016
24
2
0
Part
03/03/2016
5.00
Immersion/Soak
Alicia McCarthy Catherine York Vinh Tran
Stainless Steel
Greases
None
Gravimetric
Stainless steel coupons were weighed to get their initial weights. The bottom third of each coupon was coated in the DOW Corning Vacuum Grease. The coupons were re-weighed. The weights were recorded. The coupons were placed in the heated drop-in solvent replacement for 5 minutes. The coupons were removed out of the and placed to dry on a rack for 15 minutes. Then the final weights were taken.
The heated Fluosolv FR-100 and Fluosolv CX-500 did not perform well in removing Dow Corning Vacuum Grease.
No relation