Default object view. Click to create a custom template, Node ID: 7013, Object ID: 7012

Trial #5

Trial #5

To evaluate one of the client requested products on the supplied parts

2003

10

4

132

132

Part

06/12/2003

5.00

Ultrasonics

Jason Marshall

Nickel
Titanium

Tap water rinse

Heat Gun

One client supplied product was heated to 130 F and degassed in a Branson 200 40kHz ultrasonic unit for five minutes.  One section of tubing was placed in the tank and cleaned for five minutes.  The part was then rinsed in a tap water bath at 120 F for 15 seconds and dried using a Master Appliance Heat Gun at 500 F for 15 seconds.  The part was then analyzed for cleanliness using the performance test and microscopic inspection.

The tubes were attached to a dry air line. The end of the tube was inserted into a latex glove that was tied off at the end (to simulate the balloon). Air was turned on and run until the glove filled up to the size of medium hand. The air was shut off and the gloves were inverted and visually inspected for signs of particulate. The cleaned part left no visible signs of contamination. Visual inspection under a microscope revealed that there may have been residual lubricant still inside the tube, but there was less than the uncleaned part.

Increasing cleaning time may improve the removal of the lubricant from inside the tubing.  Additional testing may be done to determine if pressurized rinsing will also help cleaning efficiency.