Default object view. Click to create a custom template, Node ID: 6009, Object ID: 6008

Trial #0

Trial #0

To identify best way to rinse parts after cleaning with aqueous product in ultrasonic cleaning.

2006

14

1

65

65

Part

10/18/2006

5.00

Ultrasonics

Jason Marshall

Brass
Carbon Steel

Air Blowoff

Visual

Two products were selected from the lab's database of testing results. Products were selected based on contaminant removal and substrate compatibility. Both products were diluted to 5% using DI water and heated to 130 F by immersing beakers into a Branson 3510 ultrasonic tank filled with water. Solutions were de-gassed for 5 minutes.

Parts were placed into a basket and immersed into each solution and cleaned using 40 kHz ultrasonic energy for 5 minutes. After cleaning, a set of parts were removed from the cleaning and were not rinsed. These parts were dried using compressed air at room temperature for 30 seconds. Observations were made following drying. A second set of parts were rinsed in a single tap water bath at 130 F for 20 seconds, followed by the air drying and analysis. A final set were rinsed in three tap water baths, each at 20 seconds and 130 F. Drying and analysis were the same as before.

One of the two cleaners cleaned better and did not cause oxidation after sitting at room temperature following drying. Observations are listed in the table below.

Cleaner Part Description Rinse Method Observations
Detergent 8 Brass and Steel lighter No rinse Residue, parts not clean
    1 rinse Less residue than 0 rinse
    3 rinse Free of residue; may have some oxidation occurring
Polyspray Jet  Steel Eagles No rinse No visible residue
    1 rinse Clean and no residue
  Brass and Steel lighter 3 rinse Looked clean, no residue, no oxidation

The multi-stage rinsing with Polyspray Jet 790 XS looked to clean the best and leave the least residue behind.