Trial #0

Trial #0

Two chemistries were tested.

1996

4

2

168

168

Part

03/17/1996

30.00

Ultrasonics

There are no related objects.

Carbon Deposits

None

None

Visual

Two stainless steel tank valves and four sections of tank lids were cleaned for Vessel Cleaning Company. Two different chemistries were tested. One was a twenty percent solution of Delta Omega Technologies DOT 111/113, the other chemistry was a mixed solution containing Sodium Hydroxide, Rochester Midland Split and Chemex 110. Each of these solutions were used in the Crest 40kHz ultrasonic unit. Cleaning time varied from 5 minutes to 30 minutes.
SUBSTRATE MATERIAL: Aluminum Drum Lids and Stainless-Steel tank valves.
CONTAMINANTS: Carbon Black
CONTAMINATING PROCESS USED: As received

The DOT 111/113 appeared to work better than Vessel Cleaning Company’s solution on the stainless-steel valves (heavy deposits still remained).  Vessel Cleaning Company's solution was much more effective than the DOT-111/113 on the more lightly soiled tank lids.  No etching was noticed, and all light contaminant was removed (some heavy deposits still remained).  

The DOT-111/113 appeared to have some trouble in removing even the light deposits from the Aluminum.