Default object view. Click to create a custom template, Node ID: 6850, Object ID: 6849

Trial #13

Trial #13

To evaluate cleaners on supplied dirty parts following current cleaning process

2009

16

4

141

141

Part

05/21/2009

10.00

Immersion/Soak

Jason Marshall

Steel

Greases
Oil

None

Air Blowoff

Visual

The two products were selected from the previous trials based on success for removing the supplied soils using heated immersion cleaning. Both were used at full strength based on vendor recommendations. Beakers were heated to 130 F on a hot plate. Steel parts were supplied by the client with grease and oils caked on to the parts. One part was cleaned in each solution for 10 minutes using stir bar agitation. Parts were not rinsed but were dried using compressed air at room temperature for 30 seconds. Parts were visually inspected and pictures were taken.

Much of the oil and grease was visually observed to have been removed from various regions of the supplied parts. However, after cleaning and drying, both cleaning solutions left behind a residue on the parts making it difficult to assess effectiveness of the two products.

Cleaner   Part Location Observation
Bean-e-doo Threads Some solid matter removed from threads. Residue remaining 
    from cleaner. Grease still in threads
  Bolt head Rust like material gone
  Overall part Cleaner residue left on most areas but most in the threads
Smart Solve 605 Threads Some solid matter removed from threads. Residue remaining 
    from cleaner. Grease still in threads
  Bolt head Rust like material gone
  Overall part Cleaner residue left on most areas but most in the threads

Cleaned parts will be returned to for inspection to determine whether products were effective at removing the greases and oils.

No relation

Name Class Section
Document Evaluation #0 Evaluation 3
Document Evaluation #1 Evaluation 3
Powered by eZ Publish™ CMS Open Source Web Content Management. Copyright © 1999-2014 eZ Systems AS (except where otherwise noted). All rights reserved.