Default object view. Click to create a custom template, Node ID: 4498, Object ID: 4497

Project #1

Project #1

To replace the current hazardous chemical with a non hazardous one that works as well as the current.

Yes

No

No

01/22/2008

Jerry R. Lesikar

Plastic

Parts to be assembled for dormatory furniture

multiple sizes

Medium

5-10 lbs

Smooth

Hard

Simple

No

Adhesive

Yes

Parts glued and edge banded and sent to assembly to be put together into furniture

Assembly into furniture

varies

Manual Wipe

Foremost

Trichloroethylene

100

Room

Uses hazardous solvent

none

None

Used Immediately

Visual

Top concern is employee health due to long term exposure and the cost and hassel to dispose of hazrdous waste.

Using the laboratory's database for solvent cleaning substitution, the lab generated a list of products that have been used to replace TCE in adhesive removal. In addition, vendor supplied data was searched for the same parameters.

No

No

Yes

No

No

Name Class Section
Document Trial #0 Trial 3