Evaluate ultrasonic cleaning

1997

5

2

60

60

Part

09/30/1997

5.00

Ultrasonics

Jason Marshall

Stainless Steel

DI water rinse

IR Heat Lamp

Visual

The purpose of this experiment was to determine if the cleaners could remove all the oil from the parts using the most common energy level of ultrasonic cleaning (40 KHz). All the cleaning parameters from the first trial were duplicated in this trial except for the source of the mechanical energy. A 40 KHz ultrasonic tank was used in place of the stir bar agitation.

SUBSTRATE MATERIAL: Stainless steel
CONTAMINANTS: Client supplied oil

The cleaning cycle (2 min. cleaning, 30sec. rinsing and drying) proved that the use of the ultrasonics was more effective than the stir bar agitation in removing the oil.  However, all of the oil was not removed.  Therefore, the parts were sent through a second and third cleaning cycle. After each cycle, the parts were analyzed visually for cleanliness.  Of the two cleaners the Grace product removed more oil than the Fine Organics Corp product.  The extended cleaning time did allow for removal of most of the oil.

The Grace cleaning product showed very good oil removal after the six minutes of cleaning. Even though all of the oil was not removed from the parts, the length of time can be adjusted further. Also, another way to increase oil removal would be to increase the concentration of the cleaner.

The next step will be to determine better cleaning parameters using the Grace cleaning chemistry and ultrasonic cleaning.