Trial #2

Trial #2

Evaluate effectiveness for three products at increased time and concentrations

2002

9

4

86

86

Coupon

03/31/2002

10.00

Ultrasonics

Jason Marshall

Aluminum

Waxes

Tap water rinse

Heat Gun

Gravimetric

The three products that showed improvement in the previous trial were diluted to 10% using DI water in 600 ml beakers. Each solution was heated to 110 F and degassed for 5 minutes in a Crest 40 kHz Ultrasonic unit. Nine preweighed coupons were coated with the beeswax and weighed again. Three coupons were cleaned for 10 minutes followed by a tap water rinse at 120 F for 15 seconds and a heat gun drying at 300 F for 1 minute. Final weights were recorded and efficiencies were calculated.

Increasing the cleaning time and concentrations increased the efficiency for the three products tested. Inproclean and Texolite removed over 95% of the wax in the 10 minutes. The Polyspray product increased from 73% to 80%.

Cleaner Coupon 1 Coupon 2 Coupon 3 Average Std Dev
Inproclean 97.74 101.01 98.73 99.16 1.68
Texolite 98.23 98.47 94.07 96.92 2.47
Polyspray 83.29 74.56 83.16 80.33 5.00

The effective cleaners will be tested on wax removal from glass coupons using ultrasonic energy.  Cleaners to evaluated are:  Inproclean 3800, Texolite 1734 XL, Bio T 200 A, Histo Clear and Opti Clear.