Default object view. Click to create a custom template, Node ID: 6607, Object ID: 6606

Trial #5

Trial #5

To clean second supplied part under same operating conditions

2002

9

4

117

117

Coupon

05/20/2002

5.00

Ultrasonics

Jason Marshall

Glass/Quartz

Mold Releases
Waxes

DI water rinse

Heat Gun

Microphotography

A 1000 ml beaker was filled with 800 ml of cleaning solution and heated to 110 F in a Crest 40 kHz ultrasonic tank. The solution was degassed for 5 minutes. The supplied glass optic part was photographed four times using a digital camera and a microscope to establish how dirty part was. The part was immersed into the solutions and cleaned for 5 minutes using ultrasonic energy, then rinsed in a DI water spray at room temperature for 15 seconds, followed by drying with a heat gun at 300 F for 30 seconds. The part was then reanalyzed using the camera and microscope.

All parts of the optics looked cleaner after using the Opti Clean.  Magnification of camera not enough to see fine detail.  Part started to attract dust via static electricity.  See pictures of before and after.

All parts of the optics looked cleaner after using the Opti Clean.