Default object view. Click to create a custom template, Node ID: 5783, Object ID: 5782

Trial #1

Trial #1

To evaluate client supplied cleaning solution on all listed contaminants and one substrate.

1999

7

4

29

29

Coupon

08/11/1999

5.00

Immersion/Soak

Jason Marshall

Stainless Steel

Tap water rinse

Air dry

Gravimetric

The cleaning solution was used at full strength in a 600 mL beaker. The solution was heated to 130oF. Coupons were cleaned for five minutes. Rinsing was performed for two minutes using tap water at 120oF and air dried for about two hours also at room temperature. After drying is complete, final weights are recorded and efficiencies are calculated.

SUBSTRATE MATERIAL: Stainless Steel (202-316B-80)
CONTAMINANTS: Table 1 lists the contaminants and the related CAS#s for this trial.
Table 1. Contaminants Cleaned
Contaminant CAS #
Oil 64741-89-5
Ink 67-63-0, 108-88-3, 9004-70-0, 141-78-6, 64-17-5, 109-60-4
Adhesive 9010-98-4, 65997-13-9, 68083-03-4, 67-56-1, 1314-13-2, 119-47-1, 108-88-3, 8052-10-6

The Engine Degreaser was very successful in removing the adhesive and the oil from the stainless steel coupons. It was ineffective on the ink. Table 2 lists the calculated efficiencies.

Table 2. Cleaning Efficiencies

Contaminant Engine Degreaser
Adhesive 85
Ink 3
Oil 99

The Engine Degreaser proved very effective on the oil and moderately successful on the adhesive tested.  Further evaluation on other contaminants will take place.

No relation

Name Class Section
Document Evaluation #0 Evaluation 3
Document Evaluation #1 Evaluation 3
Document Evaluation #2 Evaluation 3
Powered by eZ Publish™ CMS Open Source Web Content Management. Copyright © 1999-2014 eZ Systems AS (except where otherwise noted). All rights reserved.