Trial #1

Trial #1

To reevaluate selected products using ultrasonics and higher temperatures.

2006

14

4

26

26

Coupon

08/16/2006

5.00

Ultrasonics

Jason Marshall

Copper

Tap water rinse

Air Blowoff

Gravimetric

Three products from the previous trial were diluted to 5% in 250 ml beakers using DI water and heated to 130 F in a Branson 3510 ultrasonic tank and degassed for 5 minutes.

Nine preweighed coupons were coated with the red buffing compound using a hand held swab after heating to its melting point with a heat gun. Coupons were weighed a second time to determine the amount of buffing compound added. Three coupons were cleaned in each solution for five minutes using 40 kHz ultrasonic agitation. Coupons were rinsed for 15 seconds in a tap water bath at 120 F and dried using a dry compressed air for 30 seconds. Once dry coupons were weighed a final time and product efficiencies were calculated.

Two of the three products removed over 90% of the buffing compound within five minutes of cleaning at 150 F with ultrasonic energy. The table below lists the amount of buffing compound added, the amount remaining and the efficiency for each coupon cleaned.

Cleaner Initial wt Final wt % Removed
Daraclean 283 0.8928 0.1450 83.76
  0.6233 0.0646 89.64
  0.7572 0.0131 98.27
Polyspray Jet 790 XS 0.3948 0.0023 99.42
  0.5594 0.0002 99.96
  1.2716 0.3426 73.06
XL 100 0.8591 0.1165 86.44
  0.8020 0.1768 77.96
  0.8656 0.1842 78.72

The elevated temperature and ultrasonic energy improved the effectiveness of both the Daraclean 283 and the Polyspray Jet 790 XS. These products will be tested on the supplied oil.