Default object view. Click to create a custom template, Node ID: 7086, Object ID: 7085

Trial #11

Trial #11

To evaluate client requested products on the fifth soil.

2004

12

2

6

6

Coupon

07/07/2004

5.00

Immersion/Soak

Jason Marshall

Titanium

Fluxes

Tap water rinse

Air Blowoff

Gravimetric

The three cleaners were diluted to 5% using DI water in 600 ml beakers and heated to 120 F on a hot plate.

Nine preweighed titanium coupons were coated with client supplied Wolverine Ultra Flux (1332-77-0, 10043-35-3, 7789-29-9, 11128-29-3, 151-21-3), using a hand held swab and then heated with a Master Appliance Heat Gun at 500 F for 10 minutes. Coupons were allowed to cool and then weighed a second time to determine the amount of soil added. Three coupons were cleaned in each solution for 5 minutes using stir-bar agitation. Coupons were rinsed in tap water for 15 seconds at 120 F, followed by air blow off at room temperature. Once dry, coupons were weighed a final time and efficiencies for each cleaner were calculated.

All three products removed over 99% of the second oil. The table below lists the amount of soil added, the amount remaining and the efficiency for each coupon cleaned.

Cleaner Initial wt Final wt % Removed
M Aero 1.1170 0.0014 99.87
  1.2380 0.0004 99.97
  0.8871 0.0069 99.22
M Aero NS 0.9014 0.0039 99.57
  1.3230 0.0009 99.93
  1.2541 0.0001 99.99
M 400 0.7871 0.0013 99.83
  0.9139 0.0038 99.58
  0.8060 0.0035 99.57

The supplied products will be tested on the sixth supplied soil using manual wiping at room temperature.