Default object view. Click to create a custom template, Node ID: 38499, Object ID: 60199

Project #1

Project #1

To identify and technically validate safer alternatives to Hexane used for CNC pre-cleaning of dental implant components with the goal of eliminating Hexane from production while maintaining SPC and visual measurement capability and quality.

No

No

No

02/20/2026

22% stainless steel, 23% Ti, 55% TiZr

1.5g

3g

12mm X 7mm

Small

Less than 1 lb

Smooth

Hard

Complex

Yes

60 Minuteman Rd Andover

Oil

No

Parts come off the machine one a collection bin for a few minutes

visual inspection

187,500

>30

Immersion/Soak

Transene

Hexane (Aliphatic Hydrocarbon)

ambient

Time (min) 5

None

Operator exposure to highly toxic and flammable material. Regulatory and sustainability concerns driving global phase-out. Desire to standardize globally on a safer and repeatable method.

Remove machining oils and residues to allow accurate SPC measurements (CMM, microscope, visual systems) and inspections. Deliver parts free of residues, streaking or trapped oils in threads or complex geometries.

None

Air dry

1 min

ambient

Stored

on open trays

1-4 weeks

Visual, microscopic

Thread check, gauging, CMM (coordinate measuring machine) inspection

No

Yes

No

No

No

Name Class Section
Document Trial #0 Trial 3