Trial #6
To evaluate top 5 products on supplied parts using ultrasonics cleaning.
The five successful products from the previous trials were selected to test on the supplied parts. Each product was heated to 130 on a hot plate. The heated solutions were then poured into a tall cylinder (25 ml glass graduated cylinders) and placed in a heated ultrasonic tank. Each solution was degassed for five minutes.
Two dirty parts were immersed into the solutions. The parts were placed in the upright position and cleaned for 5 minutes using a Crest 40 kHz ultrasonic tank at 130 F. Parts were then rinsed in a DI Spray for 15 seconds at room temperature and dried with compressed air for 30 seconds also at room temperature. Visual observations were made on the cleaned parts. Parts were packaged to be sent back to client for final observations.
Visually, all five products removed exterior soils. During cleaning, bubbles were observed coming out the tops of each of the parts which would signify that the cleaning solutions were getting into and out of the inner diameter of the parts.
When the parts were being packaged, one of the five products - D Greeze 500 LO left a tacky residue on the parts.
Four of the five products performed well based on the outside cleaning of the supplied parts. Finally, assessment of the inside diameters will be conducted by the client.
No relation