Trial #113
Laboratory evaluations of alternative cleaning products
There are no related objects.
Basic cleaning performance testing was conducted using ASTM G122 as the bases for cleaning.
(i) 5 minute immersion cleaning with stir bar agitation @ 120 degree F.
(ii) 30 sec manual rinse with water @120 degree F.
(iii) air drying for about 24 hours.
CONTAMINANT INFO: Quench Oil
| Product
|
Company
|
Conc.
|
Avg % Removal
|
| Solution 2000
|
Clean Safe Solutions
|
10%
|
66.9
|
Ultrasonic tests on precision clean and heavyweight are necessary to further support their effectiveness. Unlike all other cleaners used in this test, these two cleaners are reported to be aqueous and non-alkaline, non butyl cleaners, respectively.