Default object view. Click to create a custom template, Node ID: 6157, Object ID: 6156

Trial #131

Trial #131

Laboratory evaluations of alternative cleaning products

2002

0

1

450

451

Coupon

01/08/2002

5.00

Immersion/Soak

There are no related objects.

Stainless Steel

Inks

Tap water rinse

Heat Gun

Gravimetric

Basic cleaning performance testing was conducted using ASTM G122 as the bases for cleaning. 

Contaminant: ITW Dykem Corp - ink-Steel blue -DX-100
cas # : 64175, 123864, 71363, 9004700, 67630, 8004873.
EXPERIMENTAL PROCEDURE:
Cleaning : 5 min. immersion cleaning at 120 F with stir-bar agitation.
Rinsing   : 1/2 min. manual with water at 120 F.

NONE OF THE CLEANERS WORKED. There was observed increase in weight which can be contributed to the fact that water was retained by the contaminant.