Default object view. Click to create a custom template, Node ID: 6170, Object ID: 6169

Trial #144

Trial #144

Laboratory evaluations of alternative cleaning products

2002

0

1

614

615

Coupon

01/14/2002

5.00

Immersion/Soak

There are no related objects.

Stainless Steel

Inks

Tap water rinse

Heat Gun

Gravimetric

Basic cleaning performance testing was conducted using ASTM G122 as the bases for cleaning. 

Cleaning: 5 min Immersion cleaning with stir-bar agitation @ 120 F
Rinsing: 1/2 min, manual, in 102 F water (tap)
Drying : 1 min with heat gun @ 500F
Contaminant: ITW, Dykem Corp, Ink, Steel Blue - DX - 100
CAS#'s 64175, 12386

None of these cleaners were effective on the dried ink contaminant. The LF 2100 was especially ineffective, it seems to react with the ink and deposit an oily or greasy substance onto the coupon, increasing its weight dramatically. LF:  This cleaner reacted w/ the ink, changing its color from deep blue-green to purple greasy/oily film. After cleaning the ink never dried, it stayed tacky or wet.  Gravimetric analysis showed there was a significant increase in weight.

No relation

Name Class Section
Document Evaluation #0 Evaluation 3
Document Evaluation #1 Evaluation 3
Document Evaluation #2 Evaluation 3
Document Evaluation #3 Evaluation 3
Document Evaluation #4 Evaluation 3
Document Evaluation #5 Evaluation 3
Powered by eZ Publish™ CMS Open Source Web Content Management. Copyright © 1999-2014 eZ Systems AS (except where otherwise noted). All rights reserved.