Basic cleaning performance testing was conducted using ASTM G122 as the bases for cleaning.
Degasification: 5 min. in ultrasonic crest at 120 F.
Cleaning: 2 min. in ultrasonic crest at 120 F.
Rinsing: 1/2 min. manual with water at 120 F.
Drying: 1 min. with heat gun at 500 F.
Contaminant: Latex binder mix (00146)
Cas #: 9016-45-9, 766