Default object view. Click to create a custom template, Node ID: 6190, Object ID: 6189

Trial #164

Trial #164

Laboratory evaluations of alternative cleaning products

2002

0

1

634

635

Coupon

01/30/2002

1.00

Media Blasting

There are no related objects.

Stainless Steel

Adhesive

Tap water rinse

Heat Gun

Gravimetric

Basic cleaning performance testing was conducted using ASTM G122 as the bases for cleaning. 

Cleaning: Media Blast with Baking Soda in machine from BSC Co Inc, Blasted each coupon 20-30 seconds under pressure of 80-100 psi
Rinsing: 1/2 minute with tap water, manual, at 120 F
Drying: Heat gun at 500 F
Contaminant: Aroset PS 8078, Ashland Chemical

Media Blasting with baking soda is very ineffective on tacky adhesive. Used coupons 20 - 25 from trial 161. Did media blasting on 23 - 25 for standard time of 10 - 20 seconds with poor results. Media blasted coupons 20 - 22 for much longer time frame may help, but not likely.

No relation

Name Class Section
Document Evaluation #0 Evaluation 3
Document Evaluation #1 Evaluation 3