Basic cleaning performance testing was conducted using ASTM G122 as the bases for cleaning.
Degasifying: 5 min. in ultrasonic crest at 120 F.
Cleaning: 2 min. with ultrasonic agitation at 120 F
Rinsing: 1/2 min. manual with water at 120 F
Drying: 1 min. with heat gun at 500 F