Default object view. Click to create a custom template, Node ID: 6234, Object ID: 6233

Trial #208

Trial #208

Laboratory evaluations of alternative cleaning products

2002

0

1

656

656

Coupon

09/09/2002

2.00

Ultrasonics

There are no related objects.

Stainless Steel

Cutting/Tapping Fluids

Tap water rinse

Heat Gun

Gravimetric

Basic cleaning performance testing was conducted using ASTM G122 as the bases for cleaning. 

Degassing: Degassing the solution by keeping solutions in ultrasonic crest for 2 min at 120 F.
Cleaning: Ultrasonic for 2 min. at 120 F.
Rinsing: 1/2 min. manual with water at 120 F.
Drying: 1 min with heat gun @ 500F
Contaminant: Steco Corp, Tap Magic Protap (cutting fluid)
CAS# 112-80-1(>75%) Aliphatic organic acid
112-62-9 (<15%) Aliphatic organic ester

Heated ultrasonics did not change efficiency significantly.