Default object view. Click to create a custom template, Node ID: 6267, Object ID: 6266

Trial #241

Trial #241

Laboratory evaluations of alternative cleaning products

2003

0

1

704

705

Coupon

03/27/2003

5.00

Immersion/Soak

Jason Marshall

Aluminum

Coatings

Tap water rinse

Air Blowoff

Gravimetric

Basic cleaning performance testing was conducted using ASTM G122 as the bases for cleaning. 

Cleaning: 5 min Immersion cleaning with stir-bar agitation @ 120 F
Rinsing: 1/2 min, manual, in 102 F water (tap)
Drying: 30 seconds air blow off, 68 F
Contaminant: Ferrocote 5815 LVO

After cleaning, wiping was performed to see if efficiencies would increase significantly. Trial 255 shows these results.