Default object view. Click to create a custom template, Node ID: 6288, Object ID: 6287

Trial #262

Trial #262

Laboratory evaluations of alternative cleaning products

2003

0

1

717

717

Coupon

09/08/2003

5.00

Immersion/Soak

Jason Marshall

Brass

Tap water rinse

Air Blowoff

Gravimetric

Basic cleaning performance testing was conducted using ASTM G122 as the bases for cleaning. 

Four products were used at full strength, heated to 120 F on a hot plate. Twelve preweighed coupons were coated with Jackson Lea Antique Buffing Compound LM 12 (9000-70-8, 1344-28-1, 409-21-2, 1309-37-1) and allowed to dry overnight and reweighed.
Three coupons were cleaned in each solution for 5 minutes using stir-bar-agitation, rinsed in a tap water bath for 15 seconds at 120 F and dried using air blow off for 30 seconds at 68 F. Coupons were allowed to dry overnight and then reweighed a final time. Efficiencies were calculated.

Note: Bio T Foam Plus was sprayed onto coupons at room temperature and allowed to sit for 5 minutes. The cleaner was then wiped clean.

Two products removed over 95% of the buffing compound and a third removed over 85%.

AW Chesteron 278 Super Solv, Bio Chem Systems Bio T Foam Plus and DuPont DBE were all effective.