Default object view. Click to create a custom template, Node ID: 6290, Object ID: 6289

Trial #264

Trial #264

Laboratory evaluations of alternative cleaning products

2003

0

1

718

718

Coupon

09/08/2003

0.00

No relation

Jason Marshall

Aluminum

Coatings

Tap water rinse

Air Blowoff

Gravimetric

Basic cleaning performance testing was conducted using ASTM G122 as the bases for cleaning. 

Five products were used at full strength, heated to 120 F on a hot plate. Fifteen preweighed coupons were coated with Quaker Chemical Ferrocoate 5815-LVO protective coating and allowed to dry overnight and reweighed. Three coupons were cleaned in each solution for 5 minutes using stir-bar-agitation, rinsed in a tap water bath for 15 seconds at 120 F and dried using air blow off for 30 seconds at 68 F. Coupons were allowed to dry overnight and then reweighed a final time. Efficiencies were calculated.

Note: Bio T Foam Plus was sprayed onto coupons at room temperature and allowed to sit for 5 minutes. The cleaner was then wiped clean.

Only one product was partially successful in removing the coating.  Additional contact time may improve efficiencies for others as there was signs that the coating was starting to crack.

No products removed over 85% of the coating.