Default object view. Click to create a custom template, Node ID: 6309, Object ID: 6308

Trial #283

Trial #283

Laboratory evaluations of alternative cleaning products

2003

0

1

806

806

Coupon

10/21/2003

5.00

Immersion/Soak

There are no related objects.

Stainless Steel

Cutting/Tapping Fluids

Tap water rinse

Air Blowoff

Gravimetric

Basic cleaning performance testing was conducted using ASTM G122 as the bases for cleaning. 

One product was used at full strength at room temperature and seven others were heated to 130 F on a hot plate. Twenty-four preweighed coupons were coated with Monroe Fluid Tech Cool Tool II and allowed to dry for a half an hour and reweighed. Three coupons were cleaned in each solution for 5 minutes using stir-bar-agitation, rinsed in a tap water bath for 15 seconds at 120 F and dried using air blow off for 30 seconds at 68 F. Coupons were allowed to dry for a half an hour and then reweighed a final time. Efficiencies were calculated.

6 out of 8 products were effective at removing the contaminant at an efficiency rate of over 85%.