Default object view. Click to create a custom template, Node ID: 6311, Object ID: 6310

Trial #285

Trial #285

Laboratory evaluations of alternative cleaning products

2003

0

1

808

808

Coupon

10/24/2003

5.00

Immersion/Soak

There are no related objects.

Aluminum

Fluxes

Tap water rinse

Air Blowoff

Gravimetric

Basic cleaning performance testing was conducted using ASTM G122 as the bases for cleaning. 

Three products were used at full strength at room temperature and five products were heated to 130 F on a hot plate. Twenty four preweighed coupons were coated with Flux Kester Solder Flux 1544 (64-17-5, 78-92-2, 8050-09-7) and allowed to dry for a half an hour and reweighed. Three coupons were cleaned in each solution for 5 minutes using stir-bar-agitation, rinsed in a tap water bath for 15 seconds at 120 F and dried using air blow off for 30 seconds at 68 F. Coupons were allowed to dry for a half an hour and then reweighed a final time. Efficiencies were calculated.

Half of the products were effective at removing the contaminant at an efficiency rate of over 88%.